Time Behavior For [0X01] Inventory And Iso15693 Transponders - Feig Electronic OBID i-scan ID ISC.PR101 Manual

Standard-reader
Hide thumbs Also See for OBID i-scan ID ISC.PR101:
Table of Contents

Advertisement

®
OBID i-scan

Time Behavior for [0x01] Inventory and ISO15693 Transponders

All times apply to the following parameters: ISO15693 MODE = 0x0B (see
Parameters) and
3.6. CFG5:
AFI disabled
16 timeslots
only ISO15693 Transponder driver active
ONT = Only new Transponder will be send to the host
The modulation and the sub-carrier have a negligible influence on the reaction time.
The following diagrams shows the average value of timing behavior, dependent on the number of
Transponders. For certain UID's the real timing can by higher or lower as show below.
The timing is measured inclusive of the communication time at 38,4Kbaud. A modified baud rate will
slightly increase the timing but the Inventory timing is mostly determined by anticollision so you may
neglect the communication time.
FEIG ELECTRONIC GmbH
System-Manual
Anticollision.
Execution time
Tx
Rx
Communication time
Page 119 of 131
+
=
ID ISC.MR/PR/PRH101
3.5. CFG4: Transponder
H60301-3e-ID-B.doc

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obid i-scan id isc.mr101Obid i-scan id isc.prh101

Table of Contents