0Xa5] Unlock - Feig Electronic OBID i-scan ID ISC.PR101 Manual

Standard-reader
Hide thumbs Also See for OBID i-scan ID ISC.PR101:
Table of Contents

Advertisement

®
OBID i-scan

8.2.6. [0xA5] Unlock

This command unlocks the KSW - TempSens.
REQUEST-DATA
5
0xA5
MODE
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
MODE:
Bit:
Function
ADR:
UID:
Read-only serial no. of the transponder. The UID is required only in the addressed mode.
ISO-ERROR:
ISO error code of transponder response. This byte is only available if STATUS = 0x95.
FEIG ELECTRONIC GmbH
System-Manual
6
(7-14)
UID
7
6
-
-
ADR
b000
non-addressed
b001
addressed
b010
selected
7-12 (15-21)
Password
5
4
-
-
Page 89 of 131
ID ISC.MR/PR/PRH101
3
2
1
-
ADR
H60301-3e-ID-B.doc
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obid i-scan id isc.mr101Obid i-scan id isc.prh101

Table of Contents