0X2B] Get System Information - Feig Electronic OBID i-scan ID ISC.PR101 Manual

Standard-reader
Hide thumbs Also See for OBID i-scan ID ISC.PR101:
Table of Contents

Advertisement

®
OBID i-scan

6.1.12. [0x2B] Get System Information

This command reads the system information from one Transponder.
REQUEST-DATA
4
0x2B
MODE
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
RESPONSE-DATA
5
6...13
DSFID
UID
Only LS
0x00
32bits valid
MODE:
Bit:
Function
ADR:
b000
b001
b010
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
ISO-ERROR:
ISO15693 error code of Transponder response. This byte is only available if STATUS = 0x95.
DSFID:
Data Storage Format Identifier of the Transponder.
UID:
The LSB (32bits) from the Read only Serial Number of the Transponder.
AFI:
Application Family Identifier. If not supported by the Transponder, this value will return 0x00.
Manufacturer Code:
Manufacturer specific code (see:
FEIG ELECTRONIC GmbH
System-Manual
5
(6...13)
UID
14
AFI
Manufacturer
Code
7
6
0
0
non-addressed
addressed
selected
ANNEX A: Codes of Transponder
15...16
17
MEM-SIZE
IC-REF
MEM SIZE
Chip Version
5
4
0
0
Page 73 of 131
ID ISC.MR/PR/PRH101
3
2
1
0
ADR
Types)
H60301-3e-ID-B.doc
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obid i-scan id isc.mr101Obid i-scan id isc.prh101

Table of Contents