3.5. CFG4: Transponder Parameters

The parameters of the CFG4 configuration block contain general Transponder settings.
Byte
0
Contents
I-Code-
MODE
Default
0x00
Byte
7
Contents
CUSTOMER
OPTION
Default
0x00
I-Code-MODE: (only I-Code Transponder)
Bit:
Function
Mapping:
b0:
b1:
Note:
• If Mapping is set to "original I-Code Memory Model" the ISO15693 Host Command
Read Config Block[0xA0] and Write Config Block [0xA1] will not be available.
To change the Config Block 0,1,2 can now be done with Write Multiple Blocks [0x24]
on the original I-Code Address 2,3,4.
FAM-CODE: (only I-Code 1 Transponders)
Family Code to select a Transponder
APP-ID: (only I-Code 1 Transponders)
Application ID to select a Transponder
Note:
If FAM-CODE and APP-ID are zero, all I-Code 1 Transponders will response. Otherwise only the
Transponders with matching FAM-CODE and APP-ID will respond.
FEIG ELECTRONIC GmbH
System-Manual
1
2
FAM-CODE
APP-ID
0x00
0x00
8
9
0x00
0x00
7
6
5
Mapping
0
0
FEIG Memory Model (default)
Original I-Code Memory Model
3
0x00
ISO 15693
10
0x00
4
3
0
0
Page 28 of 131
ID ISC.MR/PR/PRH101
4
5
ISO 15693
MODE
AFI
0x0B
0x00
11
12
0x00
0x00
2
1
0
0
0
0
H60301-3e-ID-B.doc
6
ISO 15693
OPTION
0x00
13
ISO-Block-
size
0x04

Hide quick links: