Feig Electronic OBID i-scan ID ISC.PR101 Manual page 34

Standard-reader
Hide thumbs Also See for OBID i-scan ID ISC.PR101:
Table of Contents

Advertisement

®
OBID i-scan
SCAN-LOCK-TIME: (1 ... 65535 * 100 ms = 100 ms ... 6553,5 sec)
The SCAN-LOCK-TIME defines the period in which the Reader does not transmit the Trans-
ponder data a second time, after it has transmitted it the first time. (regardless whether the
Transponder is in the detection range of the reader during SCAN-LOCK-TIME or not). The
SCAN-LOCK-TIME starts after the data transmission from the Transponder to the Reader.
Transponder in field
SCAN-LOCK-TIME
Data output
t
:
Time to read the Transponder data
r
t
:
Data Transmission from the Reader to the host
o
t
:
SCAN-LOCK-TIME
s
As long as the SCAN-LOCK-TIME is active, the Transponder can be in the detection
range of the reader or outside of it.
DB-ADR:
Transponder address of the first data block which will be transferred in Scan-Mode.
Range: 0x00...0xFF.
See for valid addresses:
ted ISO15693 Host commands for ISO15693
D-LGT:
D-LGT defines the length of raw data which are transmitted in the Scan-Mode.
Number of data bytes to be transferred, starting with the D-START.
Example:
data block
Byte
Data
0x01
Output Data
FEIG ELECTRONIC GmbH
System-Manual
t
t
r
o
ANNEX G: Memory Model I-Code 1 Transponders
0
1
2
3
0x23
0x45
0x67
D-START = 1
D-LGT = 4
0x23
0x45
0x67
Page 34 of 131
start of read
t
s
Transponders
4
5
6
0x89
0xAB
0xCD
0x89
ID ISC.MR/PR/PRH101
t
t
r
o
and
9.1. Suppor-
7
0xEF
H60301-3e-ID-B.doc
t
s

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obid i-scan id isc.mr101Obid i-scan id isc.prh101

Table of Contents