8.2. KSW Custom Commands

These commands supports the functions of the KSW TempSens and VarioSense transponder

8.2.1. [0xA0] Set Passive

This command deactivates the RC-oscillator of the transponder. The temperature detection will be
switched off.
REQUEST-DATA
5
0xA0
MODE
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
MODE:
Bit:
Function
ADR:
UID:
Read-only serial no. of the transponder. The UID is required only in the addressed mode.
ISO-ERROR:
ISO error code of transponder response. This byte is only available if STATUS = 0x95.
FEIG ELECTRONIC GmbH
System-Manual
6
(7-14)
UID
7
6
-
-
ADR
b000
non-addressed
b001
addressed
b010
selected
5
4
-
-
Page 84 of 131
ID ISC.MR/PR/PRH101
3
2
1
-
ADR
H60301-3e-ID-B.doc
0