0X18] Destroy (Only I-Code Epc/Uid Transponders) - Feig Electronic OBID i-scan ID ISC.PR101 Manual

Standard-reader
Hide thumbs Also See for OBID i-scan ID ISC.PR101:
Table of Contents

Advertisement

®
OBID i-scan

7.2. [0x18] Destroy (only I-Code EPC/UID Transponders)

This command will render the I-Code EPC/UID Transponder permanently unable to give any replies.
Host → Reader (TYPE – I-Code EPC)
1
0x15
COM-ADR
Host → Reader (TYPE – I-Code UID)
1
0x1C
COM-ADR
Host ← Reader
1
6
COM-ADR
MODE:
Bit:
Function
TYPE:
b000
b001
EPC:
12 Byte I-Code EPC Data (electronic product code)
If the I-Code EPC data has only a length of 8 Byte, the I-Code EPC must be written left-
justified (Byte 5-12). The last 4 Bytes will be ignored.
IDD:
19 Byte IDD Data of I-Code UID
Password:
The password is of length 24 bits and must match with the content which was previously
written into the relevant section of the I-Code EPC/UID memory.
Notes:
• Only one Transponder may be in the RF-field. If more than one transponder in the field the
reader returns with status = [0x83] (RF Communication Error.)
• If the I-Code EPC doesn't match, the reader also answers with status = [0x83].
• If the command was not successfully (reader may continue read the I-Code EPC), the reader
answers with status = [0x03].
FEIG ELECTRONIC GmbH
System-Manual
2
3
0x18
2
3
0x18
2
3
0x18
7
6
5
0
0
0
I-Code EPC
I-Code UID
Page 79 of 131
4
5...16
Mode
EPC
4
5...23
Mode
IDD
4
5...6
STATUS
CRC16
4
3
0
0
ID ISC.MR/PR/PRH101
17...19
20...21
Password
CRC16
24...26
27...28
Password
CRC16
2
1
0
TYPE
H60301-3e-ID-B.doc

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obid i-scan id isc.mr101Obid i-scan id isc.prh101

Table of Contents