Error-Code for ISO15693 Transponders

Hex-value
0x01
The command is not supported, i.e. the request code is not recognized
0x02
The command is not recognized, for example: a format error occurred
0x03
The option is not supported
0x0F
Unknown error
0x10
The specified block is not available (doesn't exist)
0x11
The specified block is already locked and thus cannot be locked again
0x12
The specified block is locked and its content cannot be changed
0x13
The specified block was not successfully programmed
0x14
The specified block was not successfully locked
0xA0 - 0xDF Custom command error codes
all others
reserved for future use
FEIG ELECTRONIC GmbH
System-Manual
Response error code definition
Page 123 of 131