Input/Output Connections; Pulse Output Signals - ICP DAS USA I-8092F Getting Started Manual

Motion control module
Hide thumbs Also See for I-8092F:
Table of Contents

Advertisement

2.3 Input/Output Connections

The signal connections of all the I/O signals are described in this chapter. Please refer
the contents of this chapter befor wiring the cable between the i8092F and the motor
drivers.

2.3.1 Pulse output signals

There are 2-axis pulse output signals on I8092F, For every axis, two pairs of CW and
CCW signals are used to send the pulse train. The CW and CCW signals can also be
programmed as PULSE and DIR signals pait.
Differential-Type and Open-Collector Type, can be selected from JP2/3 and JP4/5 and are
described in section 2.2.2. The following wiring diagram is for the CW and CCW signals of the
2-axis.
Output to Motor Drivers in Differential Circuit
Open Collector TTL Output
http://www.icpdas.com
Fig. 2.8 Differential-Type pulse output circuit
Fig. 2.9 The wiring is open collector output
Two types of the pulse output signal,
20
I8092F Getting Started ManualVer.2.3

Advertisement

Table of Contents
loading