Turbofiller - Hardi COMMANDER TWIN FORCE Instruction Book

Hide thumbs Also See for COMMANDER TWIN FORCE:
Table of Contents

Advertisement

TurboFiller

Before use
• Push the handle (arrow) to unlock.
• Grab the handle to pull TurboFiller down until it clicks into locked
down-position.
After use
• Push the handle (arrow) to unlock.
• Grab the handle to push TurboFiller back in storing position until it
locks.
±
WARNING! Before releasing the lock (arrowed) always keep a
hand on the grip to avoid abrupt movement of the TurboFiller!
The TurboFiller valves and Chemical Container Rinsing lever are placed
on the backside (arrow).
TurboFiller suction valve
The valve is used simultaneously with the TurboFiller. The valve has 2
settings: Continuously open or spring loaded normally closed. Open the
valve when chemicals are to be filled into the TurboFiller and transferred
to main tank.
Suction from TurboFiller
TurboDeflector valve
This TurboDeflector valve activates the Vortex flushing of the TurboFiller.
Lift the lever to lock it in open position for continuous liquid rotation in
the hopper.
Start TurboDeflector
Chemical Container Rinsing lever
The upper lever is used for two purposes:
When the TurboFiller lid is open: For rinsing empty containers. Place the
container over the rotating flushing nozzle in the middle of the
TurboFiller to rinse the inside of the container.
When the TurboFiller lid is closed: Use the Chemical Container Rinsing
lever to rinse the hopper when the filling of chemicals is completed.
Chemical Container Rinsing
DANGER! Do not press the lever unless the multi-hole nozzle is covered by a container as spray liquid may otherwise