Change of bulbs
1. Switch off the light.
2. Loosen the screws on the lamp and remove the cover or lens.
3. Remove the bulb.
4. Fit a new bulb, refit the cover and tighten the screws.
ATTENTION! If halogen bulbs are used, never touch the bulb with your fingers. Natural moisture in the skin will cause
the bulb to burn out when the light is switched on. Always use a clean cloth or tissue when handling halogen bulbs.
Wear bushing renewal on steering
If too much play is found in the steering, the wear bushes must be renewed. This should be done at your local HARDI dealer.
Shield renewal on transmission shaft
See the manufacturer's instruction book.
Replacement of transmission shaft cross journals
See the manufacturer's instruction book.
Safety valve activation
To make the fluid system work perfectly over time, it is good practice to regularly provoke opening of the safety valve.
This avoids clogging and ensures proper function of the safety valve. This is done by turning the pressure SmartValve to
"Pressure draining" or an unused function when pump is running. This is good practice for all but particularly for sprayers
without optional equipment.
€
DANGER! Before turning pressure SmartValve to "Pressure draining" it is very important to be sure that the quick
coupler lid is correct and completely mounted to the filling stud into its locked position. Failure to do so may cause
risk of contamination and injury from quick coupler lid being "shot" off when pressurized! If not possible to mount lid
completely, lubricate the rubber seal and the grip hooks.
6 - Maintenance
101