Pressure draining (optional)

It is possible to drain to an external tank. This is done the following way:
1. Connect a hose from an external tank to the pressure quick
coupler on the sprayer.
2. Turn the Pressure SmartValve towards "External tank".
3. Turn the suction valve towards "Main tank".
4. Engage the P.T.O to start the pump.
5. When tank is drained then turn off P.T.O. again.
6. Disconnect hose and refit the quick coupler lid.
DANGER! Before turning Pressure SmartValve to "Pressure draining/TurboFiller" it is very important to be sure that the
quick coupler is correct and completely mounted to the filling stud into its locked position. Failure to do so may cause
risk of contamination and injury from quick coupler being "shot" off when pressurized! If not possible to mount
coupler completely, lubricate the rubber seal and the grip hooks.