6 - Maintenance

Level indicator wire renewal

If the wire on the level indicator has to be changed, the float guide pole is removed:
1. Remove the tank drain valve (see paragraph "Drain valve seal renewal") and loosen the fitting holding the pole in
position.
2. Pull the pole down through the drain valve hole till it is free in the top of the tank.
3. The pole can now be taken out of the tank through the filling hole.
DANGER! Do not enter the inside of the tank - the parts can be changed from the outside of the tank!

Level indicator adjustment

The level indicator reading should be checked regularly. When the tank
is empty, the float should lie on the stop pin (D) of the rod, and the O-
ring on the indicator should be positioned at the top position line (A).
ATTENTION! The wire guide wheels should be directed so they
follow the direction of the wire.
If any deviation is found, do:
1. Pull out the plug (B).
2. Loosen screws (C).
3. Adjust the length of the cord until it reads correctly.
4. Push plug (B) back in place.
÷
NOTE! For best accuracy adjustment shall be done with the
sprayer attached to the tractor normally used.

Drain valve seal renewal

If the main tank drain valve leaks, the seal and seat can be changed the
following way.
DANGER! Do not enter the inside of the tank - the parts can be
changed from the outside of the tank!
±
WARNING! Use eye / face protection mask when dismantling the
tank drain valve!
1. Make sure the tank is empty and clean.
2. The valve must be closed and the string loose.
3. Pull out the clip (A) and pull down connecting piece (B). The entire
valve assembly can now be pulled out.
4. Check cord and valve flap assembly (C) for wear, replace seal (D)
and assemble again.
5. Assemble the valve assembly again using a new valve seat (E). Lubricate O-rings (F) before assembly.
6. Fit clip (A) again.
ATTENTION! Check function of valve with clean water before filling chemicals into the tank.