Filters and nozzles

Possible options:
Mesh
Filter gauze width
30
0.58 mm
50
0.30 mm
80
0.18 mm
100
0.15 mm
*depends on selected nozzles
**not with PrimeFlow

Power consumption

Recommended tractor engine power output are as follows.
Sprayer
Hp
3300 (not TERRA FORCE)
100
4500 (not TERRA FORCE)
115
5500
130
7000 (not DELTA)
150

Brakes

Max. wear rates on brake components:
Sprayer litre
Drum dimensions
3300
400 x 80 mm
3300/4500
400 x 120 mm
5500/7000
412 x 160 mm
Hydraulic brakes
Max. hydraulic pressure: 150 bar (2176 p.s.i.)
Air brakes
Load apportioning valve pressure settings:
Relieved
0 bar
Empty main tank
2.8 bar
Half main tank
4.3 bar
Full main tank
Max. air tank pressure (6.5 bar)
EasyClean
Cyclone
Yes
-
Yes, standard
-
Yes
Yes, standard
-
-
kW
75
86
95
110
Max. drum diameter
403 mm
403 mm
414 mm
8 - Technical specifications
In-line**
-
Yes*
Yes*
Yes*
Min. lining thickness
4.0 mm
4.5 mm
5.5 mm
Nozzle
-
Yes*
Yes*
Yes*
117