Accessories
Operation and diagnostics

USB module

USB module
Interface to the PC
Connect the inverter via a USB 2.0 connection cable to a PC on which the Lenze "EASY Starter"
engineering tool is installed. Configure the inverter with the "EASY Starter" using graphical
user interfaces. You can create diagnostics with trend functions or observe parameter values.
Parameterising without supplying the inverter with voltage: in many cases, the USB interface
of the PC is sufficient for the voltage supply if you connect the inverter directly to the PC
without a hub.
USB module
Order code
I5MADU0000000S
Connecting cable
Order code
EWL0085/S
EWL0086/S
Inverters with network option EtherCAT, PROFINET or EtherNET/IP must be
supplied with an additional voltage for setting parameters if a connection cable
longer than 3 m is used.
Please observe the following for USB modules labelled as "PRE-SERIES":
Inverters with network option EtherCAT, PROFINET or EtherNET/IP must always
be supplied with an additional voltage for setting parameters.
186
Type
Parameter setting without voltage supply of the inverter is possible.
USB 2.0 connecting cable required
Length
Type
3 m
USB 2.0‑connecting cable (A-plug to micro B-plug)
5 m