Motor connection
Switching in the motor cable
Switching on the motor side of the inverter is permissible:
For safety shutdown (emergency stop).
In case several motors are driven by one inverter (only in V/f operating mode).
Please note the following:
The switching elements on the motor side must be dimensioned for with the
maximum occurring load.
Motor cable lengths
The rated data for the motor cable length must be observed.
•
Keep the motor cable as short as possible as this has a positive effect on the drive
•
behaviour and the EMC.
Several motors connected to an inverter form a group drive. In case of group drives, the
•
resulting motor cable length l
l
[m] = (l
+ l
+ l
... l
) ∙ √i
res
1
2
3
i
l
Resulting length of the motor cables
res
l
Length of the single motor cable
x
i
Number of the single motor cables
is relevant:
res
Information on electrical installation
Motor connection