Command
Front panel locks (Executive mode)
Lock front panel
Unlock front panel
View lock status
Resets
The DMS is shipped password-protected. The factory configured passwords for all accounts on this device have been set
NOTE:
to the device serial number. In the event of a complete system reset, the passwords convert to the default, which is no password.
Reset all global presets
Reset one global preset
Reset all mutes
Reset room map (outputs)
Reset individual room
Reset individual room preset
Reset whole switcher
Reset settings and delete files
Absolute reset
Information requests
Information request
Request part number
NOTE:
There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is
the overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron
firmware update, which is available at www.extron.com.
Query firmware version
Example:
X#
= Lock status
KEY:
X^
= Global preset number
X&
= Room number (for room presets) 01 through 10 (each can have up to 10 room presets [
X(
= Room preset number
X1@
= Number (quantity) of inputs
X1#
= Number (quantity) of outputs
X1$
= Board installed
X1%
= Part number
X1^
= Firmware version number to second decimal place (x.xx)
X1&
= Verbose firmware version-description-upload date/time
ASCII Command
(Host to Unit)
1X
0X
X
E ZG }
EX^ ZG }
E ZZ }
E ZR }
EX& ZR }
EX& * X( ZP }
E ZXXX }
E ZY }
E ZQQQ }
I
N
Q
Q
0 = not locked
00 through 32
00 through 10
4 , 8 , 12 , 16 , 20 , 24 , 28 , 32 , 36
4 , 8 , 12 , 16 , 20 , 24 , 28 , 32 , 36
X0 = No board installed
60 -nnnn- 01
DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Programming Guide
Response
(Unit to Host)
Exe1 ]
Exe0 ]
X#]
Zpg ]
Zpg X^]
Zpz ]
Zpr ]
Zpr X&]
Zpp X& * X(]
Zpx ]
Zpy ]
Zpq ]
V X1@ X X1# •A X1@ X X1# •S X1$
X1$
1
2
X1%]
X1^]
1.23 ]
1 = locked
C1 = 4 DVI inputs x 4 outputs
C2 = 4 DVI inputs x 0 outputs
C3 = 0 DVI inputs x 4 outputs
Additional Description
Clear all global presets and their names.
X^
Clear global preset
.
Unmute all outputs.
Clear all room definitions.
X&
Delete room
.
X&
Clear an individual room preset (
name.
Clear all ties and presets, rooms, and I/O names.
Excludes IP settings to preserve
communications. Recommended after a
firmware update.
Similar to Reset whole switcher, plus clear the
IP address to 192.168.254.254 and subnet
mask to 255.255.000.000.
... X1$
]
n
X1@
X1#
V
X
shows the number of available inputs
and outputs for this configuration.
X1@
X1#
A
X
has no meaning for this product.
X1$
X1$
X1$
S
...
shows the board type
1
2
n
installed in each slot. n is either 4 (DMS 1600),
5 (DMS 2000), 8 (DMS 3200), or 9 (DMS 3600).
See the part numbers listed on the Extron
web site, www.extron.com.
The factory installed firmware controller version is
1.23 (sample value only).
X(
s] assigned)
D1 = 4 fiber inputs x 4 outputs
D2 = 4 fiber inputs x 0 outputs
D3 = 0 fiber inputs x 4 outputs