3.6

Special Front Panel Key Sequences

Pressing a combination of front panel keys accesses additional settings.
Refill++ time: Simultaneously pressing the LEFT and RIGHT keys once brings up the
Refill++ time menu. As another method of first drop compensation, Refill++ time is
added to Refill time after the jet is idled for a defined number of seconds. Refill++ time
applies to just the first drop in both PULSE and LEVEL modes. To access Refill++,
press LEFT + RIGHT once. The screen on the right appears:
Figure 3-14: Press LEFT + RIGHT to Set the Refill++ Parameter
For RCP, enter the recipe number. AFTER is the jet idle time in seconds, and
REFILL++ is the extra refill time. For a detailed explanation, see Section
6.2 - Programming Timing Recipes (Adjust Refill Time for First Drop), and also
Appendix 1: First Drop Compensation. After entering the REFILL++ settings,
simultaneously press the LEFT and RIGHT keys twice to accept the new settings and
return to the main menu.
RS-232 Settings: Simultaneously pressing LEFT+RIGHT twice brings up the RS-232
Settings menu. This setting is explained in detail in Section 4.2 - Changing the Default
RS-232 Settings. Press LEFT+RIGHT again to return to the main menu.