7.5

Heater Commands

SH
Set Heater Temperature
The SH command allows the host to set the temperature for the Heater Controller in the
Advanjet Controller.
# nTemperature
SO
Turn Heater On/Off
The SO command allows the host to turn On or Off the heater in the controller.
# nFlag
HF
Heater Off timer
The HF command gives the host the ability to automatically turn the heater off after a
specified Jet idle time.
# nMins
Example: The following commands will set the heater temperature to 50 degree Celsius
(122 °F), the idle time to 5 minutes and turn on the heater.
SH 50;
HF 5;
SO 1;
3A5856A
Sets temperature value in degrees Celsius.
This value should be less than 75 degrees Celsius (167 °F).
Sets #nFlag; 1 = turn heater on and 0 = turn heater off
Sets the idle Jet time in minutes
Advanjet HV-2000C Jet Controller Setup and Operation
# nTemperature;
# nFlag;
# nMins;