7.3
Recipe Timing Commands (Continued)
SL
Adjust Refill Time for First Drop #nRecipeID,#Refill+,#Refill++,#DelaySec;
The SL command adjusts the Refill Time for the first dot. These values help to control
the size and quality of the first dot. Four parameters are required for this function,
defined as follows:
1
# nRecipeID
2
# Refill+
3
# Refill++
4
# DelaySec
Example: SL 0,2,4,20;
Sets the first recipe, Recipe #1
Refill+ Time is 0.2 msec
Refill++ Time is 0.4 msec
Idle Time is 20 seconds
The Refill+ Time (0.2 msec) is added to the Refill Time of Recipe #1 for every
drop in DROP mode and added only to the very first drop in LINE mode, as
described in Section 6.4. If the Jet has been idle for more than 20 seconds, then
the Refill++ Time (0.4 msec) is used for first drop adjustment.
CT
Set Drop Count and Trigger Format #nRecipeID,#TriggerFormat,#nDotCount;
The CT command set the count value for drops and the format for the trigger input.
Three parameters are required for this function, defined as follows:
1
# nRecipeID
2
# TriggerFormat
3
# nDotCount
Example #1: CT 0,0,2;
Sets the first recipe, Recipe #1
Trigger format is PULSE
Drop Count is 2.
This command will cause the Jet to dispense 2 drops when it receives a PULSE
signal from Recipe #1 Trigger.
Example #2: CT 1,1,5;
Sets the second recipe, Recipe #2
Trigger format is LEVEL
The number of drops will depend on the duration of the LEVEL signal (low) from
Recipe #2 Trigger and the single drop cycle time defined by the ST command.
The drop count value of 5 is ignored.
Page 34 of 60
Identifies the recipe; it must be between 0 and 5.
Sets the timing value in 0.1 msec units to be added to the first dot
Sets the timing value in 0.1 msec units to be added to the first dot
after the Jet is idle for # DelaySec seconds
Sets the Jet idle time used by the #Refill++ in seconds.
Identifies the recipe; it must be between 0 and 5.
Sets #TriggerFormat; 0 = PULSE and 1 = LEVEL
Sets the number of drops per trigger signal
Advanjet HV-2000C Jet Controller Setup and Operation