Recipe Timing Commands - Graco Advanjet Diaphragm-Jet HV-2000 Setup And Operation

Table of Contents

Advertisement

7.3

Recipe Timing Commands

ST
Set Recipe Timers
The ST function configures the timing values for the recipe. #RecipeID numbers 0 to 5
correspond to Recipes 1 to 6.
Seven parameters are required for this function, defined as follows:
1
# nRecipeID
2
# Refill
3 - 6
#0, #0, #0, #0
7
# Dwell
Example #1: ST 0,18,0,0,0,0,32;
Sets the first recipe, Recipe #1
Refill Time is 1.8 msec
Dwell Time is 3.2 msec
The Refill Time plus the Dwell Time set the single drop cycle time to 5msec
(1.8 +3.2) resulting in a drop frequency of 200 drops per second.
Example #2: ST 3,50,0,0,0,0,150;
Sets Recipe #4
Refill Time is 5 msec
Dwell Time is 15 msec
The Refill Time plus the Dwell Time set the single drop cycle time to 20msec
(5+15) resulting in a drop frequency of 50 drops per second
3A5856A
#RecipeID,#Refill,#0,#0,#0,#0,#Dwell;
#RecipeID 0
#RecipeID 1
#RecipeID 2
#RecipeID 3
#RecipeID 4
#RecipeID 5
Figure 7-1 - #RecipeID 0 – 5
Corresponds to Recipe #1 - 6
Identifies the recipe; it must be between 0 and 5.
Specifies the Refill Time in 0.1 msec units.
Four reserved timer values; they must all be 0.
Specifies the Dwell Time in 0.1 msec units.
Advanjet HV-2000C Jet Controller Setup and Operation


2

3

4

5

6
Page 33 of 60