Appendix 3: Digital Pressure Gauge; Appendix 3-1: Specifications - Graco Advanjet Diaphragm-Jet HV-2000 Setup And Operation

Table of Contents

Advertisement

Appendix 3: Digital Pressure Gauge

Appendix 3-1:
AP-30 Series
Two-Color Digital Display Pressure Sensor
TYPE
Model
Rated pressure
Pressure resistance
Type of pressure
Fluid type
Display power
Display resolution
Display range
Repetition accuracy
Response time (chatter prevention function)
Control output
Analog output
Temperature fluctuation for analog output
Temperature fluctuation for display
Control output hysteresis
Power supply
Current consumption
Ambient temperature
Relative humidity
Vibration
Material
Weight
3A5856A
Specifications
NEGATIVE
PRESSURE
AP-31K (P)
0 to -29.9 inHg
(0 to -101.3 kPa)
72.5 psi
Gauge pressure, air or non-corrosive gases
Air or non-corrosive gases
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43")
0.1 kPa,
1 mmHg,
0.1 inHg,
0.001 bar
-15% to +110% of F.S.
±0.2% of F.S. (5 ms or more)
2.5/5/100/500 ms (selectable)
NPN open collector: 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output
(N.O./N.C.selectable)
1 to 5 V (Load impedance: 47 kΩ min.)
±2% max. (of F.S.) of detecting pressure at 25 °C (77°F) (0 to 50 °C) (32 to 122 °F)
±1% max. (of F.S.) of detecting pressure at 25 °C (77°F) (0 to 50 °C) (32 to 122 °F)
Variable (when hysteresis mode is selected), 0.5% of F.S. in standard mode
12 to 24 VDC ±10%
50 mA (at 24 V), 90 mA (at 12 V)
0 to 50 °C (32 to 122°F), No condensation / 35 to 85% RH (No condensation)
35 to 85% RH (No condensation)
10 to 55 Hz, 1.5 mm
respectively
Front housing: Polyamide, Front panel sheet: PET, Rear housing:
Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable
Approx.120 g
Advanjet HV-2000C Jet Controller Setup and Operation
POSITIVE
PRESSURE
AP-32K (P)
AP-33K (P)
0 to 14.50 psi
0 to 145.0 psi
(0 to 100 kPa)
(0 to 1.000 MPa)
72.5 psi
217.5 psi
0.1 kPa,
0.001 MPa
2
0.001 kgf / cm
,
0.01 kgf / cm
0.02 psi,
0.2 psi,
0.001 bar
0.01 bar
0.06"
double amplitude in X, Y, and Z directions, 2 hours
COMPOUND
PRESSURE
AP-34K
29.9 to -29.9 inHg
(101.3 to -101.3 kPa)
72.5 psi
0.2 kPa,
2
,
2 mmHg,
0.1 inHg,
0.002 bar