Graco Advanjet Diaphragm-Jet HV-2000 Setup And Operation page 24

Table of Contents

Advertisement

5.2
Settings Menu (Continued)
10.
RS-232 Settings: The default settings for the Advanjet program and the
controller are as follows:
SETTING
CTS (hardware handshake)
Baud Rate
Parity
Data Length
The Advanjet program sets the value for the COM Port at startup. The program
polls each COM port in your computer and looks for the controller. Advanjet will
warn the user if it fails to find the COM port for the controller. To troubleshoot,
open Device Manager (Control Panel\System\Hardware\Device Manager) to view
a list of hardware devices installed on your computer and properties for each
device.
Figure 5-3: Assignment of COM Port Shown on Device Manager
An entry for Ports (COM & LPT) will appear on the Device Manager list when a
USB/Serial adapter cable is installed in the PC. For example, Figure 5-3 shows
that the USB-to-Serial Com Port is assigned a value of 4 (COM4).
11.
Check Status: Click on this button to check on the communication status
between the Advanjet program and the controller. The status is displayed below
the line on the left. A Ready status indicates that the communication is working.
A Com Port Error or Read Error status indicates a RS-232 cable connection
failure.
Page 24 of 60
DEFAULT
ON
57600
NONE
8BIT
Advanjet HV-2000C Jet Controller Setup and Operation
OPTIONS
ON or OFF
57600, 19200, 9600 or 4800
NONE, EVEN or ODD
8BIT or 7BIT
3A5856A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advanjet diaphragm-jet hv-2000c

Table of Contents