TT-3000E mini-C GMDSS System
4.7.2
G
ROUNDING
Connect a grounding wire between the ships structure and
AP5042 by using the dedicated grounding point found on the
rear panel of the alarm panel.
The grounding wire should have a cross section of at least
2
0.75mm
and the length should preferably be kept below 1
meter.
4.7.3
C
ONNECTING
There are two DSUB9 connectors on the back of the AP5042
Inmarsat-C Alarm Panel, one male type marked "Inm-C" and
one female type marked "Power".
The connector marked "Inm-C" is used for communication
with the TT-3000E mini-C GMDSS System. The pin-out is
shown in Table 12. For further information concerning wiring
of the communication interface, please refer to section 4.4.7.
Female DSUB 9 pin connector marked "Inm-C"
Pin
Signal
1
GND
2
GND
3
Data +
4
Data -
5
Data -
6
Termination resistor
7
Data +
8
+9V input
9
+9V input
Table 12 Pinout of "Inm-C" connector on AP5042
AP5042
Remark
Internally connected to pin 2
Internally connected to pin 1
Internally connected to pin 7
Internally connected to pin 5
Internally connected to pin 4
Strap to pin 7 to activate
Internally connected to pin 3
Internally connected to pin 9
Internally connected to pin 8
70/97