12-2 Configuration of peripheral equipments

12-2-1 Setup environment
Use the servo drive in environment of Pollution Degree 2 or 1 prescribed in IEC 60664-1. (E.g. Install inside of
the control box of IP54)
12-2-2 Power supply
100V type: Single phase 100V to 115V
200V type: (A to D-frame) Single/3-phase 200V to 240V
200V type: (E and F-frame) 3-phase 200V to 230V
(1) Use under environment of over-voltage category-II prescribed in IEC 60664-1.
(2) Use an interface power supply of DC12 to 24V, insulated type, which conforms to CE marking or
EN Standard (EN60950).
12-2-3 Circuit breaker
Connect a circuit breaker which conforms to IEC Standard and is UL recognized (UL Listed and
Marked) between the power supply and the noise filter without fail.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
R2
Power
supply
Circuit
Noise filter
breaker
Surge
absorber
Control box
Controller
Insulated power
supply for interface
CN-X5
Noise filter for
Servo
Noise filter for
signal line
driver
signal line
L1
L2
L3
L1C(r)
L2C(t)
CN-X4
Protective earth (PE)
+10%
50/60Hz
-15%
+10%
50/60Hz
-15%
+10%
50/60Hz
-15%
Motor Company, Matsushita Electric Industrial Co., Ltd.
No.SX-DSV01676
- 42 -
Servo
motor
RE
U L