A. Technical Appendix
A.1
Technical specifications of the CPV valve terminal with direct con
nection for Smart Distributed System
General
Temperature range:
operation
storage/transport
Relative humidity
Protection class as per EN 60 529
Connector plugged in or fitted with
protective cap
Protection against explosion
(as per EU guideline 94/9/EG, EN 50021 and
EN 50281−1−1), do not disconnect when under
tension
Valves
Operating voltage of bus interface/internal logic
Operating voltage
rated value
tolerance
Current consumption
rated value
tolerance
Residual ripple
Electrical isolation
Festo P.BE−CP−SD8−...−EN en 0503b
− 5 °C ... + 50 °C
−20 °C ... + 70 °C
95 %, non−condensing
IP 65
II 3 G/D EEx nA II T5 X − 5 °C Ta + 50 °C
T 80 °C IP65 (year of manufacture see Ex−identifi
cation on the product).
Plugs or adapters of the electric connections
must comply at least with protection class IP64!
See Pneumatics manual type P.BE−CPV−...
DC 24 V
11.5 ... 25 V
50 mA
" 20 %
4 Vpp (within tolerance)
Bus interface optically isolated
A−3