1. Installation

1.2.1 Setting possibilities

1
Setting Automatic
mode*)
*) Manual mode: all other DIL switch settings for baud rate
Fig. 1/2: Setting the automatic mode on the DIL switch
Festo P.BE−CP−SD8−...−EN en 0503b
The CPV valve terminal offers two possibilities for setting the
station number and the baud rate. There are two DIL switches
and rotary switches under the switch cover for this purpose.
The following modes are possible:
automatic
S
manual
S
Automatic mode: baud rate and station number
The station number can be set in automatic mode by means
of the "Handheld Activator" from Honeywell. The baud rate
will be recognized automatically by the CPV valve terminal.
Manual mode: baud rate and station number
In manual mode, the station number can be set with the ro
tary switches on the CPV valve terminal. The baud rate is set
by means of the DIL switches.
Please note
S No settings need to be undertaken on the CPV valve
terminal for operation in automatic mode (normal
usage).
Certain settings must be made for starting the integrated self
test. These settings will be described in section 3, Diagnosis.
1
1−5