1. Installation

1.3.3 Selecting the power unit

1−14
Warning
S Use only PELV circuits as per IEC/DIN EN 60204−1 (Pro
tective Extra−Low Voltage, PELV) for the electrical supply.
Consider also the general requirements for PELV circuits
in accordance with IEC/DIN EN 60204−1.
S Use power supplies which guarantee reliable electrical
isolation of the operating voltage as per IEC/DIN EN
60204−1.
By the use of PELV circuits, protection against electric shock
(protection against direct and indirect contact) is guaranteed
in accordance with IEC/EN 60204−1 (Electrical equipment for
machines, General requirements).
The current consumption of a CPV valve terminal depends on
the number of valve coils. We recommend the following:
Use only closed−loop power units.
When selecting the power unit, check that it provides
S
sufficient output. If necessary, ascertain the total current
consumption in accordance with the following table.
Include an EMERGENCY STOP function in the load voltage
S
circuit for the CPV valve coils.
Festo P.BE−CP−SD8−...−EN en 0503b