Identification; Explosion Protection Identification; Identification "X - WAGNER TOPFINISH DD10 Alu NiP Translation Of The Original Operating Manual

Pneumatic double diaphragm pump
Table of Contents

Advertisement

Operating manual Pneumatic double diaphragm pump TOPFINISH DD10 Alu NiP
3   Identification
3   IDENTIFICATION
3.1   EXPLOSION PROTECTION IDENTIFICATION
As defined in Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device type
Pneumatic double diaphragm pump TOPFINISH DD10
Manufacturer
Wagner International AG
9450 Altstätten
Switzerland
 
 II 2 G Ex h IIB T4 Gb X
CE
European Communities
Ex
Symbol for explosion protection
II
Device class II
2
Category 2 (zone 1)
G
Ex-atmosphere gas
Ex
Ignition protection
h
Ignition protection for non-electrical devices
IIB
Explosion group
T4
Maximum surface temperature < 135 °C; 275 °F (with drying protection
active)
Gb
Zone 1 high safety level
X
Special notes (see Chapter Identification "X" [8 10])
3.2   IDENTIFICATION "X"
The maximum surface temperature corresponds to the permissible product temperature.
This and the permissible ambient temperature can be found in Chapter Technical data.
Safe Handling of WAGNER Spray Devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
4 Knocking or pushing metal against metal is to be avoided.
4 Do not drop the device.
Maximum surface temperature
The maximum surface temperature of the pump depends on the operating conditions
(heated product) and not on the device (frictional heat).
Ignition temperature of the coating product
4 Ensure that the ignition temperature of the coating product is above the maximum
surface temperature.
Ambient temperature
The permissible ambient temperature range is: 4 °C to 40 °C; 39 °F to 104 °F.
Electrostatic surface spraying
4 Do not spray device parts using electrostatic equipment.
10
Order number DOC 2366672 | Edition 08/2020