Issue
Camshaft rotates for more than 5
ERR3
minutes to find Home position.
Power failure longer than 8hrs
- - : - -
occurred.
AC transformer or motor are not
connected.
Controller will not
regenerate
Defective motor.
automatically.
Turbine blocked or defective and
calendar override set to off.
Controller
regenerates at
Controller set incorrectly.
wrong time of day.
9.2.

Valve

Issue
Flowing or
Valve stem return spring is weak.
dripping water at
Valve disc cannot close because of
drain or brine line
debris.
after regeneration.
Low water pressure.
Restricted drain line.
Injector plugged.
Valve will not draw
Injector defective.
brine.
Air check valve closes prematurely on
255 valve.
Debris is flapper 1 preventing
complete opening or flapper 1
damaged.
Ref. MKT-IM-037 / B - 17.12.2018
Installer Manual Evolio 255 - Troubleshooting
Cause
Cause
Reset and recovery
If motor keeps rotating indefinitely,
replace the following components in
this order:
wire harness;
motor;
optical sensor;
controller.
See 8.5. Cleaning and maintenance,
page 62.
Press
to reset the time.
Connect the power.
Replace motor.
Check turbine and controller settings.
Correct time setting according to
instructions.
See 5.4.4. Regeneration time, page 44.
Reset and recovery
Replace the spring.
Remove debris.
Set pump or pressure regulator to
maintain 1.38 bar (20 psi) dynamic at
softener's inlet.
Change drain to remove restriction.
Clean injector and screen.
Replace injector.
Put controller momentarily into brine
cycle (C2).
Replace or repair air check if needed.
Check flapper 1, clean seat and
flapper, replace if necessary.
79 / 90