Brine Tank And Brine Well Cleaning - Pentair Evolio 255 Installer Manual

Table of Contents

Advertisement

Installer Manual Evolio 255 - Maintenance

8.5.3. Brine tank and brine well cleaning

No.
CAUTION
Do not pull on the cables. Release the connectors from controller (1) by pressing on their
locking clips.
A
Acceding from behind the softener, disconnect the controller (1).
B
Remove the softener cover (2).
C
Remove the brine tank cover (5).
D
Remove the remaining salt from brine tank (8).
E
Remove the brine well cover (6).
F
Remove the remaining brine from brine well (7).
G
Clean the brine tank (8), the brine well (7) and the salt funnel (3) with water and sponges.
CAUTION
Do not lay down or flip over the softener to empty the brine tank. 
Using a water vacuum, remove the cleaning waste and remaining water from brine tank
H
(8) and from brine well (7).
I
Refit the brine well cover (6).
J
Refit the brine tank cover (5).
K
Refit the softener cover (2).
Acceding from behind the softener, connect the controller (1), see 4.5.9.3 Evolio 255
L
controller connection, page 37.
M
Fill the brine tank (8) with salt, see 8.3. Adding salt, page 61.
N
Close the cover (4).
64 / 90
Operation
Ref. MKT-IM-037 / B - 17.12.2018

Advertisement

Table of Contents
loading

Table of Contents