Installing the Manual Air Relief Valve

The manual air relief valve and pressure gauge are included with
this filter to help ensure safe operation of the equipment. Always
maintain these components in good working condition.
1. Remove the Manual Air Relief Valve and the pressure gauge from the
accessories package included with your filter.
2. Thread the manual air relief valve into the threaded hole at the top of the
filter.
Note: Hand tighten only! Over tightening the valve can cause
damage to the tank or valve connection threads.
3. Verify that the valve is positioned to safely direct purged air or water
away from electrical equipment or anything that might be damaged.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.
Water discharged from an improperly positioned filter or
valve can create an electrical hazard that can cause severe
personal injury as well as damage property.
4. Remove the plug from the top of the manual air relief valve with a 9/16-inch wrench.
5. Wrap the pressure gauge connection threads with thread seal tape (two full wraps of tape will be enough).
6. Thread the pressure gauge into the top of the manual air relief valve. Hand tighten only!
7. Follow Start-Up Instructions on page 6 exactly.
CLEAN AND CLEAR
PLUS Cartridge Filter Installation and User' s Guide
®
PRESSURE
GAUGE
VALVE
PLUG
VALVE STEM AND
COVER
VALVE
BODY
FILTER TANK
FIGURE 2
3