INTRODUCTION
The Pentair® Everpure® Endurance SC High-Flow Filtration systems are designed
to treat up to 200,000 gallons of water per SEN cartridge change cycle. The
systems use a pretreatment Hollow Fiber Ultrafilter (HFUF), 2, 3 or 4 fine filter
cartridges and a 2SR-BW scale inhibiting cartridge.
INSPECTION
Before mounting the Everpure Endurance SC High-Flow system, use the table
and illustration to verify the parts and quantities. If any parts are missing, contact
Customer Service at 630.307.3000 (Main) / 800.942.1153 (US only) or email at
cseverpure@pentair.com.
1
2
8
9
10
PENTAIR® EVERPURE® ENDURANCE® SERIES WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE
Endurance SC High-Flow Triple 1.1
4
3
12
11
EV943742 ENDURANCE SC HIGH-FLOW QUAD 1.1
Endurance SC High-Flow Quad 1.1
1. Manifold with Bracket
2. Shroud
3. Hollow Fiber Ultrafilter (HFUF)
4. Pretreatment Housing
5. Housing Wrench
6. 2SR-BW Cartridge
7. SEN Cartridge
8. Port Plug for SEN Installed
9. Storage Tank Assy
7
10. 3/4" Hose, 15 inches Long for
5
6
11. 3/8" Tubing, 12-foot Lengths for
12. Electrical Adapter
13. Bagged O-rings
13
14. Bag with two (2) Oetiker Clamps
14
15
15. Silicone Grease
Parts
Tank Connection
Flushing
(Attached to Control)
and two (2) Plastic Snap Grips
for 2SR-BW Cartridge
Twin
Triple
Quad
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
4
2
1
0
1
1
1
1
1
1
2
2
2
1
1
1
2
2
2
1
1
1
3
3
3

Advertisement

Table of Contents
loading

Summary of Contents for Pentair EVERPURE ENDURANCE SC

  • Page 1 3. Hollow Fiber Ultrafilter (HFUF) INSPECTION 4. Pretreatment Housing Before mounting the Everpure Endurance SC High-Flow system, use the table 5. Housing Wrench and illustration to verify the parts and quantities. If any parts are missing, contact Customer Service at 630.307.3000 (Main) / 800.942.1153 (US only) or email at 6.
  • Page 2: Important Please Read

    Drain the water that is inside the tank by opening the Not for residential use. For food service applications only. drain valve or by other means. 2 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 3: Operating Specifications

    • Outlet Manifold: 3/4" FPT (19 mm) • Backwash: 3/4" (19 mm) I.D. Tube • Everpure 2SR-BW cartridge: 1/2" (13.6 mm ) barb • Flush ports: 3/8" (9.5 mm ) barb PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE • 3...
  • Page 4: Installation Procedure

    5. Attach the second piece of 3/8" I.D. tubing to the fitting on the Manifold Rinse Valve ("Figure 1"). Use one of the spring clamps to Figure 3 secure. Run the other end to a drain. 4 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 5 Inlet Valve Flush Coffee to display the FR, VR and TR information. You must now perform an Applications initial flush and cartridge activation. Drain 2SR-BW Figure 4 PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE • 5...
  • Page 6 6 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 7 <3.0 200 gal displayed. 2. The first display is: Use these settings as a general recommendation for your application. For more detailed information, contact Technical Support. PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE • 7...
  • Page 8 13. Open the HFUF rinse valve to drain until bleach smell is gone. Flush Sanitize Port 14. Close the HFUF rinse valve. Valve 15. Open the manifold inlet valve. 16. Resume operation. Sump Connection Figure 5 8 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 9: Cartridge Replacement

    Screw Slowly open inlet valve. 15 minutes. manual ush cycles. housing into head and Open the tank valve. hand tighten. Rinse for 30 minutes. PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE • 9...
  • Page 10 25 25 16 16 32 32 27 27 33 33 17 17 14 14 31 31 15 15 21 21 SILICONE LUBRICANT 18 18 30 30 10 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 11 NSF/ANSI Standards 42 and 53 for the reduction of the claims specified on the Performance Data Sheet and at www.nsf.org. AS/NZS 3497 WM-40224 Global-Mark.com.au Water Treatment Appliance - E359339 PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE • 11...
  • Page 12: Troubleshooting

    Check flow again. If still low, replace HFUF and contact technical support for additional recommendations. Low flow to cartridge manifold. Cartridge manifold valve not Open cartridge manifold valve. fully open. 12 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 13 Water runs to drain for four (4) Controller malfunction. Contact technical support. seconds, stops and repeats. PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE • 13...
  • Page 14 Make sure controller is set to four (4) second flush. Tank must be installed with outlet port down. Contact technical support. Replace tank. 14 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 16 Southeast Asia | 390 Havelock Road, | #04-01 King’s Centre | Singapore 169662 | 65.6768.5800 Tel | cseverpure@pentair.com All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners.

Table of Contents