8.5.7.4 Motor and camshaft replacement
No.
Remove the softener and valve covers, see 8.5.2. Covers removal (softener and valve),
A
page 63.
B
Disconnect the motor (4) from the optical sensor (1).
C
Remove the white locking pin (3) securing the motor (4).
D
Turn the motor (4) counter clockwise and slide it out of its position.
E
Slide the camshaft (2) backwards until it is released from its mounting boss, then lift it up.
F
Change motor (4) and/or camshaft (2).
CAUTION
Do not push the flappers down with the camshaft, otherwise damages may occur.
Put the camshaft (2) back in its backplate location leaving the camshaft slightly angled on
G
the left of the flappers when looking at the valve from the front.
Push on the flappers from left to right with the camshaft (2), rotate it manually until the 2
H
arrows on the top plate and camshaft (5) are aligned.
I
Slide the camshaft (2) forwards until it fit completely in its mounting boss.
J
Slide the motor (4) in its position and turn it clockwise.
K
Remount the white locking pin (3) securing the motor (4).
L
Connect the motor (4) to the optical sensor (1).
Remount the softener and valve covers, see 8.5.2. Covers removal (softener and valve),