FLUSH BUFFER TANK (CONTINUED) CONNECT TO EQUIPMENT
9. Let ATM fill until tank is full. ATM tank system status
light turns from blue to green.
10. Repeat Steps 6 through 8 for final flush of ATM tank.

ADJUST BLENDING VALVE

11. Adjust blending valve during ATM tank filling to TDS
levels per desired settings. Review TDS levels from
digital TDS meter.
12. Adjust values plus or minus on the blend valve.
Monitor consistency when set.
13. Let the tank fill completely with the set optimized
water. ATM tank system status light turns from blue
to green.

CONNECT TO EQUIPMENT

14. Connect end of outlet tubing to equipment.
• If garden hose connection is not required –
use alternate connection to ½" ID tubing (not
included).
• If using garden hose fitting to ½" hose, secure
with clamp.
a. Separate the hose barb adapter into three parts:
threaded fitting, barbed flange, gasket. Slide band
clamp onto hose first and threaded fitting second.
b. Insert barbed flange into hose.
c. Push until edge of flange is flush with hose tip.
d. Insert gasket into threaded fitting.
e. Slide band clamp to end of hose and tighten screw.
15. Open outlet valve on RO processor to allow
optimized water to enter equipment.
• Water will begin to enter equipment.
• Complete final check for leaks.
• Reinstall ATM tank cover and 6" access lid.
SYSTEM INSTALL AND FLUSHING COMPLETE.
Treated water is in use at equipment.
• It may take several hours to completely fill the
tank and fully pressurize the system. Make sure to
check for leaks when fully pressurized.
NOTE: The blended water tubing/piping and associated
fittings connecting the RO blended water outlet to
the equipment being serviced should be food-grade
material that meets NSF® Standard 51, 61, or similar,
with a minimum pressure rating of 100 psi (6.9 bar,
0.69 MPa). The RO/blended water may react with
metal piping, creating a corrosive condition in addition
to imparting an objectionable taste. Plastic pipe or
reinforced beverage tubing are generally very good
material choices for RO water distribution piping. The
size of the blended water tubing/piping should be
1/2-inch (12.7 mm) O.D. minimum.
PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE