8.5.2. Covers removal (softener and valve)
No.
CAUTION
Do not pull on the cables. Release the connectors from controller (1) by pressing on their
locking clips.
A
Acceding from behind the softener, disconnect the controller (1).
B
Remove the softener cover (2).
C
Unlock the valve cover (3) from the slide clips (4) (one on each side of the valve).
D
Remove the valve cover (3).
Reverse above procedure steps to rebuild. See 4.5.9.3 Evolio 255 controller connection,
E
page 37.
Ref. MKT-IM-037 / B - 17.12.2018
Installer Manual Evolio 255 - Maintenance
Operation
63 / 90