Installing The Manual Air Relief Valve - Pentair FULLFLOXF Q Series Installation And User Manual

Cartridge style d.e. filter
Table of Contents

Advertisement

Installing the Manual Air Relief Valve

The manual air relief valve and pressure gauge are included with this filter
to help ensure safe operation of the equipment. Always maintain these
components in good working condition.
1. Remove the HiFlow™ Manual Air Relief Valve and the pressure gauge
from the accessories package included with your FullFloXF
Cartridge Style D.E. Filter.
2. Thread the manual air relief valve into the threaded hole at the top of
the filter tank.
Note: Hand tighten only! Over tightening the valve can cause
damage to the tank or valve connection threads.
3. Verify that the valve is positioned to safely direct purged air or water
away from electrical equipment or anything that might be damaged.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. Water
discharged from an improperly positioned filter or valve can create
an electrical hazard that can cause severe personal injury as well
as damage property.
4. Remove the plug from the top of the manual air relief valve with a 9/16" wrench.
5. Wrap the pressure gauge connection threads with thread seal tape (two full wraps of tape will be enough).
6. Thread the pressure gauge into the top of the manual air relief valve. Hand tighten only!
7. Follow Start-up Instructions exactly (page 8).
Q-Series
®
XF
®
FULLFLO
Q-SERIES Cartridge Style D.E. Filter Installation and User' s Guide
Figure 2
3
PRESSURE
GAUGE
VALVE
PLUG
FILTER
TANK

Advertisement