Checklist - Before Machine Start-Up; Installing The Mains Cable - HAKO Scrubmaster B120 R Operating Manual

Hide thumbs Also See for Scrubmaster B120 R:
Table of Contents

Advertisement

3.3
Checklist – before machine start-up
No. Description
1
Checking the parking area for signs of leaks. Cables and tanks must not
show any sign of leaks or damage
2
Installing the mains cable, see section 3.3.1
3
Mounting the brushes and squeegee, see chapter Maintenance
4
Adjusting the driver's seat, if necessary, see section 3.3.2
5
Checking the battery charge and recharge it as required, see section 5.3
6
Emptying the waste water tank and clean it as required, see section 5.5
7
Filling the solution tank (see chapter Maintenance) and add detergent
according to the manufacturer's specifications
3.3.1

Installing the mains cable

A
Fig. 11:
1. Loosen the bolts of the cover Fig. 11-A using the supplied socket wrench
and remove the cover.
2. Route the cable of the mains plug Fig. 11-B through the opening in the
bracket Fig. 11-C. Ensure that the side of the strain relief without a latch
faces the front towards the opening.
3. Press the strain relief into the bracket until all latches have engaged.
4. Plug the mains plug Fig. 11-D straight and firmly into the holder.
5. Reinstall the cover using the available screws.
03-7177-00.fm
Putting into service
B
C
D
37