Maintenance and Servicing
5.4.4

Cleaning the solution tank

Attention
Overflowing water! Only open the cleaning opening Fig. 28-21 when
the solution tank is empty.
Note
To facilitate loosening and closing the cover of the maintenance
unit, use the supplied handle Fig. 28-A.
1. Empty the solution tank, see section 5.4.3.
2. Turn and remove the cover of the maintenance opening Fig. 28-29.
3. Unscrew the cover of the cleaning opening Fig. 28-21.
4. Feed the water hose through the cleaning opening and clean the solution
tank thoroughly.
5. After cleaning the tank, close the cleaning opening with the cover.
6. Place the cover onto the maintenance opening and screw tight.
7. After filling the solution tank, check the cover of the maintenance unit for
leak tightness. If necessary, screw the cover tighter.
5.4.5

Cleaning the fresh water filter

Check the filter sieve Fig. 30-B of the fresh water filter Fig. 28-24 weekly and
clean or replace it as required.
Fig. 30:
1. Close the ball cock Fig. 28-B.
2. Turn and remove the filter cover Fig. 30-A.
3. Remove the filter sieve Fig. 30-B from the filter housing and clean it under
running water. Replace the filter sieve as required.
4. Reinsert the filter sieve and filter cover and open the ball cock.