Testing The Programmer Hardware - Equinox Systems FS2003 User Manual

Portable isp programmer
Table of Contents

Advertisement

2.8 Testing the programmer hardware

a
Apply power to the programmer
If you have a 'Current Limit' on your power
supply, turn it to approximately 20mA and
then gradually increase it until the
programmer 'FAIL' LED starts to FLASH.
b
No Programming Projects Loaded
NO / INVALID
PROJECT LOADED!
c
Check the programmer firmware version
EQUINOX-TECH UK
FS2003 Ver:2.41
d
Check the programmer serial number,
build revision and build date
SN:619 1.01
DATE 19-1-2004
32
Programmer circuitry powers up to 5.0V.
Target Vcc LED illuminates
The LED will illuminate if a target voltage
between 3.0 and 5.0V is detected.
FAIL LED flashes to indicate that the
programmer has rebooted. *** The FAIL LED no
longer flashes with firmware version 2.46 or
greater)
The programmer display now initialises to
show the programmer type, firmware version
etc. See 2.7(b), (c), (d).
If the programmer has never been used
before or the on-board FLASH Memory
Store has been erased, then the
programmer will display the message:
'No / Invalid Project Loaded'. This is
normal as the programmer 'FLASH
Memory Store' is empty so the
programmer cannot be used in
Standalone Mode.
It is not possible to check the
programmer information until a valid
project is uploaded. Please upload a
valid project to the programmer using
EQTools and then try again.
The programmer display now shows the
programmer type and the firmware
version.
e.g. 2.37.
You can check that you have the very
latest firmware version by viewing the
'Configit – Firmware Update Utility' on
the Equinox website.
After 2 seconds the display will update to show
the following information:
Serial Number (SN): eg. 619
Hardware Build Version: eg. 1.01
Build date: eg. 19 /1/2004