Voltage Detection
LED
10 PC Control Software The programmer can be controlled using:
11 EQTools / ISP-PRO
PC requirements
12 Power Supply
Options
13 Voltage range
14 Vpp Voltage
Generator
15 DC Power Connector
(jack socket)
16 Target Voltage
measurement
17 Max. current through
programmer
14
detected.
•
Threshold detection voltage: approx 3.1V
As standard:
•
EQTools
•
Upload Wizard (integrated with EQTools)
•
ConsoleEDS EVAL – Command Line control
Optional chargeable upgrades:
•
ASCII Text Communications Mode
•
ISP-PRO
•
Standalone Upload Wizard
•
ConsoleEDS PRO – Command Line control
PC running Windows 95 / 98 / 2000 / ME / NT4 / XP
There are 3 possible modes for powering the Programmer /
Target System:
•
Programmer is powered from the Target System (3.0 –
5.0V)
•
Programmer powers the Target System (+5.0V only)
•
Programmer and Target System are independently
powered (Programmer at 9.0 -12V, Target System at 3.0
– 5.0V)
•
Device Programming voltage range: 3.0 – 5.0V
•
Programmer Internal Vcc Voltage: 5.0V
•
Possible Target System voltage range: 3.0 – 5.0V
On Board +12.0V Vpp Voltage Generator
(Applies +12.0V to RESET pin for Atmel ATtiny HV
programming)
DC Power Connector
•
2.5 mm Jack Socket – Centre Positive
•
9.0 – 12.0V DC regulated @ 500mA (worst case)
•
Mates with Power Supply Adaptor supplied with
programmer
•
DC Power Lead also supplied with programmer if a
customer power supply is to be used.
•
The programmer can measure the Target Voltage in
either EDS or Standalone Mode.
•
Measurement Voltage range: 3.0 – 5.0
Tolerance: +/-3%
This refers to the maximum current which the programmer can
supply from the internal Vcc rail
FS2003 ISP Programmer - User Guide V1.07 – 1
3.1
2.3
st
September 2007