YASKAWA DX200 Instructions Manual page 35

Options for motofit function engineering support tool
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

HW1481731
3
Operation Procedure
3.3
Operation for Creating Fitting JOB
– Turn the servo ON by the enable switch of PP, and press the
{START} button on the I/F Panel. The adjustment operation starts.
At this time, the {START} button does not activate unless the
OPERATION is set to PERM. To set to PERM, press the switch by
pressing [Interlock].
The operation by FSE-Tool is not available unless the [PC MODE] is
valid.
When no operation is given from the I/F Panel after 20 seconds from
pressing the {Complete Setting} button on PC, the message "PP
wasn't operated." appears on the PC, and the operation is
terminated. This time can be changed at "Waiting time until PP
operated" in the Main Menu described in chapter 3.3.2 "Detailed
Operation Step" . To execute the adjustment, click the {Complete
Setting} button from PC again.
The Tuning Step 2 and MotoFit execution follows the same
operation described as above.
3-18