9. Specifications
Normal overload 110% for 1 minute
Mains Supply 3 x 380 - 480 VAC
Frequency converter
Typical Shaft Output [kW]
Typical Shaft Output [HP] at 460 V
Encapsulation
IP 20
IP 21
IP 55
IP 66
Output current
Max. input current
9
1.
2.
3.
4.
130
Continuous
(3 x 380-440 V) [A]
Intermittent
(3 x 380-440 V) [A]
Continuous
(3 x 440-480 V) [A]
Intermittent
(3 x 440-480 V) [A]
Continuous kVA
(400 V AC) [kVA]
Continuous kVA
(460 V AC) [kVA]
Max. cable size:
(mains, motor, brake)
2
[[mm
/AWG]
Continuous
(3 x 380-440 V ) [A]
Intermittent
(3 x 380-440 V ) [A]
Continuous
(3 x 440-480 V) [A]
Intermittent
(3 x 440-480 V) [A]
Max. pre-fuses
1)
[A]
Environment
Estimated power loss
at rated max. load [W]
Weight enclosure IP20 [kg]
Weight enclosure IP 21 [kg]
Weight enclosure IP 55 [kg]
Weight enclosure IP 66 [kg]
4)
Efficiency
For type of fuse see section
American Wire Gauge
Measured using 5 m screened motor cables at rated load and rated frequency
The typical power loss is at normal load conditions and expected to be within +/- 15%
(tolerance relates to variety in voltage and cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Lower efficiency
motors will also add to the power loss in the frequency converter and vice versa.
If the switching frequency is raised from nominal the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and cus-
tomer load may add up to 30W to the losses. (Though typically only 4W extra for a fully
loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement
inaccuracy must be allowed for (+/- 5%).
MG.20.M2.02 - VLT
P37K
P45K
37
45
50
60
C1
C1
C1
C1
C1
C1
73
90
80.3
99
65
80
71.5
88
50.6
62.4
51.8
63.7
50/1/0
66
82
72.6
90.2
59
73
64.9
80.3
100
125
698
843
4)
45
45
45
45
45
45
0.98
0.98
Fuses
®
is a registered Danfoss trademark
®
VLT
Operating Instructions
P55K
P75K
P90K
55
75
90
75
100
125
C1
C2
C2
C1
C2
C2
C1
C2
C2
106
147
177
117
162
195
105
130
160
116
143
176
73.4
102
123
83.7
104
128
104
128
96
133
161
106
146
177
95
118
145
105
130
160
160
250
250
1083
1384
1474
45
65
65
45
65
65
45
-
-
0.98
0.98
0.99
AQUA Drive