Installer Manual Siata V132-SFE-EV-VIRIDION - Programming
Using this feature with volumetric immediate mode for regeneration will not allow to save water and
salt since the regeneration will be done only when 100% of the resin is exhausted.
6.2.

Display

1. Days of the week
2. Parameter display
3. Animated graphic
gauge
4. Low salt alarm
5. Customer's area(*)
6. Maintenance request
icon
7. Regeneration icon
8. Battery operation icon
(*): The customer's logo may be included on the display if requested by the customer. Contact Pentair for further information.
48 / 110
→ 1: Monday;
→ 2: Tuesday;
→ 3: Wednesday;
→ 4: Thursday;
→ 5: Friday;
→ 6: Saturday;
→ 7: Sunday;
→ Flashing if regeneration is enabled for that day.
→ Clock;
→ Remaining volume capacity.
→ Current water consumption;
→ Remaining treatable volume.
→ Appears when low salt level is detected.
→ For customer's logo.
→ Appears when softener needs technical maintenance.
→ Flashes in programming mode;
→ Flashes during brining;
→ Appears during regeneration.
→ Appears when the controller is operating on battery.