6.5.
Statistics
The statistics menu displays some of the module's historical data.
A
To access to this menu, press and hold
B
Use
to switch to the next parameter in the statistics menu.
Note
The display of treated water is scrolling to allow display of more than 9999 litres.
Note
When the brining variable function Vb (brining option) is disabled (i.e. with OFF status)
optimisation values E:xx are all set to E:00.
Note
Data on the time and date of the latest regenerations are present only if regenerations have
been carried out.
Note
While the statistics are displayed, the regeneration icon is on, if not otherwise indicated.
Data
1
xxxx
Number of regenerations carried out.
2
SAxx
Number of regenerations remaining before triggering the salt alarm.
3
FFxx
Number of days elapsed since the last regeneration.
4
M3xxxxxx.xx
Water treated in m
5
Hxxxxx
Number of hours elapsed since first installation.
6
LMxxxx
Average consumption since first installation in L/h.
7
P OFF/ON
Sensor presence: OFF or ON.
8*
Xx:xx
Time and date of past regenerations.
01
Regeneration was launched in instantaneous manual mode.
M xx
02
Regeneration was launched in delayed manual mode at the programmed time.
01
Automatic regeneration launched in timed mode (SH:00).
Automatic regeneration launched in combined mode (SH:01) because volume
9*
02
exhausted.
A xx
Automatic regeneration launched in combined mode (SH:01) because
03
maximum number of days for obligatory regeneration has been reached.
04
-
Ref. MKT-IM-009 / C - 08.06.2018
Installer Manual Siata V132-SFE-EV-VIRIDION - Programming
for 5 seconds.
Description
3
.
65 / 110