Outlet water hardness
Note
This option is displayed only if SH (regeneration mode) is set to 1 or to 2.
Mandatory
Make sure the mixing device is correctly set up to match with the programmed value.
Mandatory
Use the same unit as the one used for the inlet hardness.
Set the outlet water hardness in °f (French degrees), °d (German degrees)
or mg/L of CaCO
.
3
A
Use
and
to set the hardness.
B
Press
to validate and switch to the next parameter.
Resin exchange capacity
Note
This option is displayed only if SH (regeneration mode) is set to 1 or to 2.
Mandatory
Use the same unit as the one used for the hardness.
Mandatory
In case the mixing device is installed downstream the meter, set up this parameter to 0.
Note
The resin exchange capacity can be set from 1 to 10 in °f·m
g of CaCO
/L
3
Set the resin exchange capacity.
A
Use
and
to set the exchange capacity.
B
Press
to validate and switch to the next parameter.
Salt dosage
Note
The salt dosage can be set from 80 to 200 g/L.
Set the quantity of salt in gram per liter of resin to be used for each
regeneration.
A
Use
and
to set the dosage.
B
Press
to validate and switch to the next parameter.
Ref. MKT-IM-009 / C - 08.06.2018
Installer Manual Siata V132-SFE-EV-VIRIDION - Programming
.
Resin
3
3
/L or 
/L, °d·m
53 / 110