Installer Manual Siata V132-SFE-EV-VIRIDION - Programming
Prescaler free for volumetric sensor
Note
The prescaler free can be set from 0.1 to 99,9.
Note
The prescaler free is set by default to 14 (applies to SIATA turbine with only one magnet).
Note
This option is displayed only if FP (pre-scaled flag) is set to 0.
Set the prescaler free.
A
Use
and
to set the prescaler free.
B
Press
to validate and switch to the next parameter.
Number of regenerations before salt alarm
Note
The number of regenerations before salt alarm can be set from 0 - CO - 99.
Note
CO is a salt alarm generated by resistivity check of the drained water during the brine draw
phase.
Set the number of regenerations before salt alarm light up on the
controller's display.
A
Use
and
to set the number of regenerations.
B
Press
to validate and switch to the next parameter.
Days enabled for regeneration
Note
This option is displayed only if SH (regeneration mode) is set to 0.
Set the days enabled for regeneration. The display shows "dx y" where "x"
is the day of the week (1 - 7) and "y" shows whether the selected day is
enabled for regeneration "1" or not "0".
For each enabled day, the top of the display shows the relevant flashing
icon.
A
Use
to edit the setting of the selected day "x".
B
Use
to enable or disable the selected day "y".
C
Press
to validate and switch to the next parameter.