Pentair SIATA V132-SFE-EV-VIRIDION Installer Manual page 97

Table of Contents

Advertisement

Issue
Micro-switch support damaged.
Cam not fixed.
Micro-switch stick damaged.
Micro-switch damaged.
FR01 end cycle
alarm.
Wiring problem.
Motor problem.
The controller
displays wrong
parameters.
The controller is
The controller is out of program.
blocked, whatever
button is pressed
it does not gives
feedback on the
display.
Controller
EEprom parameters reading error/
displays ErEE or
EEprom statistics reading error.
ErES.
Inhibit signal active.
The controller
does not start
regeneration.
Bad programming.
Ref. MKT-IM-009 / C - 08.06.2018
Installer Manual Siata V132-SFE-EV-VIRIDION - Troubleshooting
Cause
Reset and recovery
Open the controller box and check the
integrity of the plastic parts holding
the micro-switch.
Check if the cam is properly fixed by
the circlip.
Check if the metal stick which closes
the micro-switch is damaged.
Dismount the micro-switch and try to
actuate it manually. If the controller
goes back in service the micro-switch
is working, if this is the case check for
mechanical problems.
If the controller does not go back in
service, the micro-switch is damaged
or there is a wiring problem.
Using the electrical diagrams check if
the wiring of the micro-switch is
properly done.
Check the integrity of the harness.
Check if the motor is running. Check
motor wiring and the harnesses
integrity.
Check if motor shaft is linked to pinion
gear and torque transfer to pinion
during motor rotation.
Dismount the box and press the reset
hardware button. If this does not solve
the problem change the electronic
board.
If these parameters are displayed
continuously, the board is damaged.
Check if there is a shortcut between
the inhibit terminal ports.
Check if the controller is well
programmed based on the system
configuration.
97 / 110