6. Purge Control Solenoid Valve
A: REMOVAL
1) Disconnect the ground cable from battery.
2) Disconnect the connector and hoses of purge
control solenoid valve, and then remove the purge
control solenoid valve.
• 2.0 L model
• 2.5 L model
Purge Control Solenoid Valve
EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)
IN-00203
EC-02015
EC-00223
EC(H4SO 2.0)-7
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
⋅
19 N
m (1.9 kgf-m, 14.0 ft-lb)
• 2.0 L model
• 2.5 L model
NOTE:
Connect the evaporation hose as shown in the fig-
ure.
• 2.0 L model
(B)
(A)
EC-02015
EC-00223
EC-02016