How to Order
Frequency converter data
Mains
P
m
type
[kW]
T7
1.1
T7
1.5
T7
2.2
T7
3
T7
4
T7
5.5
T7
7.5
T7
11
T7
15
T7
18.5
T7
22
7
7
T7
30
T7
37
T7
45
T7
55
T7
75
Table 7.16 T7, Vertical Braking 40% Duty Cycle
Horizontal braking: Duty cycle 10% and maximum 120 s repetition rates according the reference brake profile. Average power corresponds to 6%.
Vertical braking: Duty cycle 40% and maximum 120 s repetition rates according the reference brake profile. Average power corresponds to 27%.
Cable cross-section: Recommended min. value based upon PVC-insulated copper cable, 30
All cabling must comply with national and local regulations on cable cross-sections and ambient temperature.
Thermal relay: Brake current setting of external thermal relay. All resistors have a built-in thermal relay switch N.C.
The IP54 is with 1,000 mm fixed unscreened cable. Vertical and horizontal mounting. Derating required by horizontal mounting.
IP21 & IP65 are with screw terminal for cable termination. Vertical and horizontal mounting. Derating required by horizontal mounting.
The IP20 is with bolt connection for cable termination. Floor mounting.
Illustration 7.2 Horizontal Loads
100%
Illustration 7.3 Vertical Loads
98
VLT
FC 302
R
R
R
rec
min
br.nom
[Ω]
[Ω]
[Ω]
620
830
630
513
600
570
340
403
415
243
292
270
180
216
200
130
156
145
94
113
105
69.7
76.2
72
46.8
55.5
52
36.0
44.7
42
29.0
37.5
31
22.5
29.1
27
18.0
23.5
22
13.5
19.3
15.5
13.5
15.7
13.5
8.8
11.5
11
150/160%
®
AutomationDrive FC 301/FC 302 Design Guide, 0.25-75 kW
Vertical braking 40% duty cycle
Brake resistor data
Danfoss part number
P
Screw
br.cont.
[kW]
Wire IP54
terminal
IP21
0.360
-
175u3108
0.570
-
175u3110
0.790
-
175u3112
1.130
-
175u3118
1.700
-
175u3122
2.200
-
175u3106
3.200
-
175u3132
4.200
-
175u3142
6.000
-
8.000
-
10.000
-
14.000
-
17.000
-
21.000
-
26.000
-
36.000
-
150/160%
MG33BF02 - Rev. 2013-12-20
Screw
Bolt
terminal
connection
IP65
IP20
175u3109
-
175u3111
-
175u3113
-
175u3119
-
175u3123
-
175u3107
-
175u3133
-
175u3143
-
-
-
175u3242
-
-
175u3243
-
-
175u3244
-
-
175u3201
-
-
175u3202
-
-
175u3205
-
-
175u3209
-
-
175u3212
° C ambient temperature with normal heat dissipation.
Installation
Cable
Thermo
cross
relay
section
[A]
[mm
2
]
1.5
0.8
1.5
1
1.5
1.3
1.5
2
1.5
2.8
1.5
3.7
1.5
5.2
1.5
7.2
2.5
10.8
2.5
13.9
4
18
10
23
10
28
16
37
16
44
25
57
Need help?